Celadon Systems, Inc.

Document Actions

VersaTile™ on Mounting Plate

product.jpg
  • Optimized for DC parametric test and single site WLR
  • Temperature compensated for use from-65°C to +300°C
  • fA level leakage measurements
  • Compatible with quick disconnect triaxial cable harnesses
  • Quasi-Kelvin connections available
  • Several Connector options Available

P/N Parametric Style Leakage Fempto Amps per Volt Settling time in seconds Settling Time Pin to pin Leakage in Fempto Amps per volt Probe Replacement Probe Type Probe Card Wiring Maximum Number of Probes Minimum Sustained Operating Temperature Maximum Sustained Operating Temperature Ownership Cost Suggested Cable/Connector Method Recommended Prober Size Typical Applications
TV19LL Low Leakage 5 fA/V 10 Fast 5 at 10 seconds Requires Factory Trained Person with Aligner Single Conductor Coax
25 -65°C 300°C Medium Coax or Triax 150 mm and Above Modeling, Device Characterization, Applications for fast wafer stepping to collect high accuracy data
TV19HT Functional Test and High Temperature Test Less than one 1 pA/V 10 Not specified Not Specified Requires Factory Trained Person with Aligner Single Conductor Single Conductor
50 -65°C 300°C Low Coax or Triax 150 mm and Above Modeling, Device Characterization
TV19LC Functional Test and High Temperature Test Less than one 1 pA/V 10 Not specified Not Specified Requires Factory Trained Person with Aligner Single Conductor Direct Probe to PCB Connection
100 -65°C 300°C Low Coax, Single Conductor, Ribbon or Plain Wire 150 mm and Above Functional Test, High Temperature Test
TV22LL
Low Leakage
5fA/V
10
Fast
5 at 10 seconds Requires Factory Trained Person with Aligner Single Conductor Coax
25
-65°C 300°C Medium
Coax or Triax 150 mm and Above Modeling, Device Characterization, Applications for fast wafer stepping to collect high accuracy data
TV22HT
Functional Test and High Temperature Test
Less than one 1pA/V
10
Not Specified Not Specified Requires Factory Trained Person with Aligner Single Conductor Single Conductor 50
-65°C 300°C Low Coax or Triax 150 mm and Above Modeling, Device Characterization
TV22LC
Functional Test and High Temperature Test Less than one 1 pA/V
10
Not Specified Not Specified Requires Factory Trained Person with Aligner Single Conductor Direct Probe to PCB Connection 100
-65°C 300°C Low Coax, Single Conductor, Ribbon or Plain Wire 150 mm and Above Functional Test, High Temperature Test

  • Mounting Method: VersaPlateTM
  • Temperature Compensated: YES
  • Supports Multi-Site Probing: No/ Not applicable
  • Maximum Coverage Area: 28 mm
  • Crash Resistance: Rigid and Fault Tolerant, Slots protect probe from Damage
  • Probe Self Alignment Slots: Yes - cavity captured
  • Die to Die Pitch: Does not apply

The Celadon VersaTileTM got its name because the product is easily reconfigurable and field installable for many different probing applications. This allows users to maintain the same probe for many different applications such as WLR, Functional Test and Parametric test. Up to 16 VersaTilesTM can be installed in a Celadon Probe Card Holder called a Celadon Modular AdapterTM.