VersaTile™ on Mounting Plate
![]() |
|
| P/N | Parametric Style | Leakage Fempto Amps per Volt | Settling time in seconds | Settling Time | Pin to pin Leakage in Fempto Amps per volt | Probe Replacement | Probe Type | Probe Card Wiring | Maximum Number of Probes | Minimum Sustained Operating Temperature | Maximum Sustained Operating Temperature | Ownership Cost | Suggested Cable/Connector Method | Recommended Prober Size | Typical Applications |
| TV19LL | Low Leakage | 5 fA/V | 10 | Fast | 5 at 10 seconds | Requires Factory Trained Person with Aligner | Single Conductor | Coax |
25 | -65°C | 300°C | Medium | Coax or Triax | 150 mm and Above | Modeling, Device Characterization, Applications for fast wafer stepping to collect high accuracy data |
| TV19HT | Functional Test and High Temperature Test | Less than one 1 pA/V | 10 | Not specified | Not Specified | Requires Factory Trained Person with Aligner | Single Conductor | Single Conductor |
50 | -65°C | 300°C | Low | Coax or Triax | 150 mm and Above | Modeling, Device Characterization |
| TV19LC | Functional Test and High Temperature Test | Less than one 1 pA/V | 10 | Not specified | Not Specified | Requires Factory Trained Person with Aligner | Single Conductor | Direct Probe to PCB Connection |
100 | -65°C | 300°C | Low | Coax, Single Conductor, Ribbon or Plain Wire | 150 mm and Above | Functional Test, High Temperature Test |
| TV22LL |
Low Leakage |
5fA/V |
10 |
Fast |
5 at 10 seconds | Requires Factory Trained Person with Aligner | Single Conductor | Coax |
25 |
-65°C | 300°C | Medium |
Coax or Triax | 150 mm and Above | Modeling, Device Characterization, Applications for fast wafer stepping to collect high accuracy data |
| TV22HT |
Functional Test and High Temperature Test |
Less than one 1pA/V |
10 |
Not Specified | Not Specified | Requires Factory Trained Person with Aligner | Single Conductor | Single Conductor | 50 |
-65°C | 300°C | Low | Coax or Triax | 150 mm and Above | Modeling, Device Characterization |
| TV22LC |
Functional Test and High Temperature Test | Less than one 1 pA/V |
10 |
Not Specified | Not Specified | Requires Factory Trained Person with Aligner | Single Conductor | Direct Probe to PCB Connection | 100 |
-65°C | 300°C | Low | Coax, Single Conductor, Ribbon or Plain Wire | 150 mm and Above | Functional Test, High Temperature Test |
- Mounting Method: VersaPlateTM
- Temperature Compensated: YES
- Supports Multi-Site Probing: No/ Not applicable
- Maximum Coverage Area: 28 mm
- Crash Resistance: Rigid and Fault Tolerant, Slots protect probe from Damage
- Probe Self Alignment Slots: Yes - cavity captured
- Die to Die Pitch: Does not apply
The Celadon VersaTileTM got its name because the product is easily reconfigurable and field installable for many different probing applications. This allows users to maintain the same probe for many different applications such as WLR, Functional Test and Parametric test. Up to 16 VersaTilesTM can be installed in a Celadon Probe Card Holder called a Celadon Modular AdapterTM.